Measurement example


Observation of partial discharges while using a hipot tester as a voltage source

Apply a high voltage after connecting the tester’s positive terminal to a stator’s U-phase and its negative terminal to the stator’s V-phase while the stator’s neutral point remains unconnected. Then compare variations in the voltage at which partial discharges begin in a stators with good insulation and in a stator whose U- and V-phase coils are in contact.

Current and voltage waveforms when 1.0 kV AC is applied to a non-defective stator.

Current and voltage waveforms when 1.5 kV AC is applied to a non-defective stator.

Current and voltage waveforms when 1.0 kV AC is applied to a stator with a pseudo-defect.

Equipment used:

Automatic insulation / withstanding HiTester 3153

  • Test voltage: 60Hz AC
    Increasing from 1000V in 100V increments

Memory HiCorder MR6000

  • Sampling speed: 200MS/s
  • Storage time: 2.5s
  • Coupling method: AC coupling

Current probe CT6711

  • Range: 0.5A
  • Output rage: 10V/A
  • Frequency band: DC to 120MHz

Contact information

Do you have any questions or a specific inquiry? We are ready to find your measurement solution.

Please send us a message to our contact email address or contact a HIOKI partner in your country.