Measurement example


Calculate Inverter Output Power, Motor Power, and Motor Efficiency Using Waveform Calculations

Calculate motor power, motor efficiency, and inverter output power after measurement using high-speed waveform calculations and display the results using the instrument’s X-Y display function. The ability to use the X-Y display for waveform calculation results as well as input signals from measurement units means you can perform a broad range of analyses. Additionally, X-Y analysis can be performed at user-specified areas of the recorded fluctuating waveform, since you can choose waveform areas for generating an X-Y display.

Equipment used:

Memory HiCorder MR6000/MR6000-01

4CH Analog unit

4CH Analog unit
U8978

3CH Current unit

3CH Current unit
U8977

Freq unit

Freq unit
8970

Strain unit

Strain unit
8969

Differential probe

Differential probe
9322

AC/DC Current probe

AC/DC Current probe
CT6841-05

Connenction cord

Connenction cord
L9197

Torque sensor(strain gage-type converter)
(For more information about the sensor, please contact the sensor manufacturer.)

Demo Video

Memory HiCorderMR600

Demo Video

Memory HiCorderMR600

Demo Video

Memory HiCorderMR600

Please accept cookies for 'external media' and reload this page to display all videos. You can turn on cookies here:

[borlabs-cookie type="btn-cookie-preference" title="Adjust cookie settings"/]

Contact information

Do you have any questions or a specific inquiry? We are ready to find your measurement solution.

Please send us a message to our contact email address or contact a HIOKI partner in your country.



Contact
News
This site is registered on wpml.org as a development site.